Susan Spearfisherman 9710 23rd Way N, Palm Beach Harbor, FL

Exterior Photos

1 Exterior Property Photos

 

Interior Photos

1 Interior Property Photos

 

Property Description

1 Structure

Home faces approximately: South • Structure Type: Single Family • Structure height: One story structure • Occupied: No. • In Attendance: Buyer's Agent
All utilities were on except: Water was off
Observations:
• Based on the condition of the home, we recommend an evaluation by a licensed general contractor.

Grounds

1 Driveway/Walkway Condition

Driveway Material(s): Concrete, Pavers • Walkway Material(s): Concrete, Brick, Pavers
Observations:
• Walkway had large and displaced crack(s) visible.

• Driveway/Walkway surface was raised/settled. Trip hazard noted.

2 Porch/Patio Condition

Porch Material(s): Concrete • Patio Material(s): Carpet • Screening/Lanai present

3 Fences/Gates Condition

Fence/Gate Material(s): Wood, PVC Polyvinyl chloride, which is used in the manufacture of white plastic pipe typically used for water supply lines.
Observations:
• Gate(s) need adjustment/repair.

• Fence were damaged.

• Gate(s) were damaged.

Foundation

1 Foundation Condition

Foundation Type: Concrete Slab
Observations:
• Foundation was not fully visible

2 Grading Condition

Level site
Observations:
• Landscaping and vegetation was poorly maintained and overgrown.

• Two large tree stumps are present in the front yard

Exterior Features

1 Exterior Walls Condition

Observations:
• House should be painted in the near future.

2 Trim Condition

Trim Material(s): Metal
Observations:
• were not fully visible.

3 Gutters & Downspouts Condition

Gutter type: Patrial Gutters • Gutter material: Metal
Observations:
• Gutters were filled with debris and the drains were blocked.

Garage

1 Garage/Carport Structure Condition

Attached garage • Garage/Carport Type: Double Car
Observations:
• Settlement cracks up to 1/8" inches were visible.

2 Garage/Carport Floor Condition

Garage/Carport Floor Material: Concrete

3 Firewall/Ceiling Condition

Observations:
• Ceiling seam separation was visible.

• Attic pull down ladder was not fire-rated.
(See NACHI Standard of Practice article -
https://www.nachi.org/inspecting-residential-attached-garages.htm) .

• Holes/gaps should be repaired with fire-rated material.

4 Door to Interior Condition

Door to the interior was a fire-rated door

5 Vehicle Door Condition

Vehicle Door Style: Roll-up
Observations:
• While operational at the time of the inspection the garage vehicle door has reached or exceeded the end of its useful life and may need replacement in the near future.

6 Vehicle Door Opener Condition

Manufacturer: Chamberlian/Liftmaster
Observations:
• Electronic eye safety feature did not operate when tested.

• While operational at the time of the inspection the vehicle door opener has reached or exceeded the end of its useful life and may need replacement in the near future.

• Electronic eye(s) were missing/not installed.

7 Door to Exterior Condition

Observations:
• Moisture damage was visible at the door and/or door jamb.

• Lock was damaged.

Lawn Sprinklers

1 Lawn Sprinklers Condition

Control box location: Garage • Number of Zones: 4. Number of active zones: 4.
Observations:
• Sprinkler heads should be adjusted for proper coverage. Sprinkler spraying on structure and appliances.

Electrical System

1 Electrical Service Condition

Service Entry Type: Below Ground • Number of Conductors: 3
Observations:
• Service wiring was in good condition: Yes.

2 Main Panel Condition

Brand/Model: Square D • Panel Age: Original • Panel Location: Garage
150 • Circuit Type: Circuit breakers • Is amperage sufficient for current usage? Yes
Observations:
• Electrical panel was in good condition: Yes.

3 Sub-Panel A Condition

Brand/Model: Intermatic • Panel Age: 15-20 Yrs • Panel Location: Pool equipment
100 • Circuit Type: Circuit breakers • Is amperage sufficient for current usage? Yes
Observations:
• Electrical panel was in good condition: Yes.

4 Wiring Condition

Wiring Type: Sheathed Non Metallic (NM) rubber insulated copper branch wire, Sheathed Non Metallic (NM), BX, Conduit
Observations:
• Light(s) were tested and not operational at multiple locations.

• Outlet(s) were not operational at exterior.

5 GFCI Condition

Observations:
• Bathroom
GFCI A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system. reset outlet was at the Garage.
• Weatherproof covers were damaged/missing at exterior outlet(s).

GFCI (Ground Fault Circuit Interrupter) outlet(s) was damaged at garage outlets.

Cooling System

1 Cooling System 1 Condition

Cooling Unit Location: Left Side • Manufacturer: Carrier • Age of unit: 2013 • Size in Tonnage: 3 Ton • Cooling System Type: Heat Pump
Observations:
• Cooling system operated: Yes.

• Cooling system was near or exceeded the end of its useful life (10-15 yrs.) and may need replacement in the near future.

• Proper trap was not installed at the condensation line.

Heating System

1 Heating System 1 Condition

Location: Garage • Manufacturer: Carrier • Age of unit: 2013 • Size in Tonnage: 3 Ton • Power Source: Electric Furnace
Observations:
• Heating system operated: Yes

• Heating system was near or exceeded the end of its useful life (10-15 yrs.) and may need replacement in the near future.

• Gaps/damage at the plenum should be sealed.

2 Distribution Condition

Distribution Type(s): Flexible & Rigid Insulated Ducts • Ducts were not fully visible
Observations:
• Air leaks were detected at the visible connections.

Thermostat & Air Filter(s)

1 Thermostat(s) Condition

Materials: Thermostat Location: Hallway

2 Air Filter(s) Condition

Materials: Filter Location(s): Primary Bedroom, Hallway, At Base of Heating Unit

Plumbing System

1 Main Line & Valve Condition

Main Valve Location: Left side • Age of main line: Original
Main Line Material(s): Copper piping
Observations:
• Visible main line was in good condition: Yes

2 Supply Lines Condition

Supply Line Material(s): Copper piping • Age of Piping System: Supply piping was original
Observations:
• Visible supply piping were in good condition: Yes

3 Drain Lines Condition

Drain Line Material(s): PVC /CPVC • Drain/Waste/Vent Piping Estimated Age: Original
Observations:
• Unused sink drain in garage should be capped - dry trap, will allow sewer gases to escape.

• Visible drain lines were in good condition: Yes

4 Water Heater 1 Condition

Water heater location: Garage • Manufacturer: Rheem, Whirlpool • Age of unit: 2009 • Water heater type: Electric • Size of water heater: 38 Gallons
Observations:
• Water heater was in good condition: Yes

• Water heater was near or exceeded the end of its useful life (10-12 yrs.) and may need replacement in the near future.

Roof System

1 Main Roof Condition

Roof Style/Shape: Gable style • Asphalt Architectural Shingle • Roof Permit Date:4-17-2007 • Estimated age of the roof covering: 16 Yrs • Estimated remaining life of the roof covering:5 years • Roof Inspection Method: Roof was walked
Observations:
• Damaged/Loose roofing material(s) were visible at multiple locations. An evaluation and repair should be completed by a qualified licensed roofer.

2 Roof Flashing Condition

Roof flashing features: Soffit vents, Vent caps, , Roof ridge vents, Gable vents, Dryer vent Valley flashing Sheet metal or other material used to line a valley in a roof to direct rainwater down into the gutter system. features: Closed Valley Flashing

3 Attic Condition

Attic Access Location(s): Garage access, Hallway access • Truss Configuration: Roof engineered trusses • Roof framing: 2x4 • Ceiling framing: 2x4 • Insulation Types: Loose fiberglass, Blanket/Batt fiberglass
Observations:
• Attic was not fully visible due to insulation, ductwork and height of structure.

• Insulation had been moved/disturbed, leaving low coverage areas.

Exterior Doors

1 Exterior Doors Condition

Exterior Door Types: Front Single Entry Door, Sliding Glass Doors, Storm Door(s), Screen Door(s)
Observations:
• Tracks and rollers on the sliding doors should be cleaned, adjusted and lubricated for proper operation on a regular basis.

Interior Features

1 Interior Doors Condition

Interior Door Type(s): Hollow core wood
Observations:
• Door rubbed/stuck at primary bedroom.

2 Window(s) Condition

Metal/Double-pane/Single-hung • Glass block
Observations:
• Window tension spring(s) were damaged at multiple locations.

• Locks were missing/damaged at family room.

3 Interior Walls Condition

Interior Wall Materials: Drywall, Tile, Wall cover over drywall

4 Ceilings Condition

Interior Ceiling Materials: Drywall

5 Flooring Condition

Flooring Materials: Tile, Carpet
Observations:
• Tile flooring was disbonded at family room. Hollow sound can be heard when the flooring was tapped.

6 Smoke Detector Condition

Smoke Detector Locations: Hallway, Outside primary bedroom
Observations:
• Smoke detectors were not present/installed at all required areas.

• CO detector(s) were not present and should be installed for safety.

• Smoke detector(s) did not respond when tested at Hallway.

7 Laundry Condition

Location: Garage • Exclusion: A washer and/or dryer was present. These units were considered portable appliances, beyond the scope of this inspection and not inspected. A courtesy check may be completed – understand units may work differently when full.

8 Ceiling Fan(s) Condition

Observations:
• The ceiling fan(s) wobbled at the living/family room.

Kitchen

1 Kitchen Cabinets Condition

Cabinet Types: Laminate
Observations:
• Cabinets were worn.

2 Kitchen Counters Condition

Counter Type(s): Laminate
Observations:
• Counter(s) were worn.

3 Kitchen Sink Condition

Observations:
• Moisture stains/damage was visible under sink.

4 Garbage Disposal Condition

Observations:
• Manufacturer: Badger

5 Dishwasher Condition

Observations:
• Manufacturer: Kenmore

• Dishwasher did not operate under normal operating conditions.

6 Oven/Stove-top Condition

Observations:
• Manufacturer: GE

• Power Source: Electric

• Oven light did not operate.

• Oven was not functioning properly.

7 Refrigerator Condition

Observations:
• Manufacturer: Samsung

• Refrigerator drinking water supply works, but icemaker did not supply ice.

8 Ventilation Condition

Observations:
• Manufacturer: Nutone

Bathrooms

1 Bathroom Locations

Observations:
• Primary bathroom.

• Hallway bathroom

2 Sink(s) Condition

Observations:
• Dry stain(s) were visible under sink at hallway bathroom.

3 Toilet(s) Condition

Observations:
• Toilet was loose at the floor at all bathrooms.

4 Shower(s) Condition

Observations:
• Enclosure should be caulked/grouted at all bathrooms.

• Cracked tiles were visible at primary bathroom.

• Wall at the exterior of shower enclosure was damaged at the primary bathroom.

Exclusions

1 Excluded Features

• Pool/Spa was not included in inspection unless requested. An additional fee will apply.

Glossary


TermDefinition
GFCI A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system.
PVC Polyvinyl chloride, which is used in the manufacture of white plastic pipe typically used for water supply lines.
Valley Flashing Sheet metal or other material used to line a valley in a roof to direct rainwater down into the gutter system.

Report Summary


Maintenance & Monitor

Foundation

Grading Condition Item: 2 • Landscaping and vegetation was poorly maintained and overgrown.
• Two large tree stumps are present in the front yard

Exterior Features

Exterior Walls Condition Item: 1 • House should be painted in the near future.
Gutters & Downspouts Condition Item: 3 • Gutters were filled with debris and the drains were blocked.

Garage

Firewall/Ceiling Condition Item: 3 • Attic pull down ladder was not fire-rated.
(See NACHI Standard of Practice article -
https://www.nachi.org/inspecting-residential-attached-garages.htm) .
Vehicle Door Condition Item: 5 • While operational at the time of the inspection the garage vehicle door has reached or exceeded the end of its useful life and may need replacement in the near future.
Vehicle Door Opener Condition Item: 6 • While operational at the time of the inspection the vehicle door opener has reached or exceeded the end of its useful life and may need replacement in the near future.

Electrical System

Wiring Condition Item: 4 • Light(s) were tested and not operational at multiple locations.
GFCI Condition Item: 5 • Weatherproof covers were damaged/missing at exterior outlet(s).

Heating System

Heating System 1 Condition Item: 1 • Heating system was near or exceeded the end of its useful life (10-15 yrs.) and may need replacement in the near future.

Roof System

Attic Condition Item: 3 • Insulation had been moved/disturbed, leaving low coverage areas.

Interior Features

Flooring Condition Item: 5 • Tile flooring was disbonded at family room. Hollow sound can be heard when the flooring was tapped.
Ceiling Fan(s) Condition Item: 8 • The ceiling fan(s) wobbled at the living/family room.

Kitchen

Oven/Stove-top Condition Item: 6 • Oven light did not operate.

Bathrooms

Shower(s) Condition Item: 4 • Cracked tiles were visible at primary bathroom.

Material Defects

Grounds

Driveway/Walkway Condition Item: 1 • Walkway had large and displaced crack(s) visible.
• Driveway/Walkway surface was raised/settled. Trip hazard noted.
Fences/Gates Condition Item: 3 • Fence were damaged.
• Gate(s) were damaged.

Garage

Firewall/Ceiling Condition Item: 3 • Holes/gaps should be repaired with fire-rated material.
Vehicle Door Opener Condition Item: 6 • Electronic eye(s) were missing/not installed.
Door to Exterior Condition Item: 7 • Moisture damage was visible at the door and/or door jamb.
• Lock was damaged.

Electrical System

Wiring Condition Item: 4 • Outlet(s) were not operational at exterior.
GFCI Condition Item: 5 GFCI A special device that is intended for the protection of personnel by de-energizing a circuit, capable of opening the circuit when even a small amount of current is flowing through the grounding system. (Ground Fault Circuit Interrupter) outlet(s) was damaged at garage outlets.

Cooling System

Cooling System 1 Condition Item: 1 • Proper trap was not installed at the condensation line.

Heating System

Heating System 1 Condition Item: 1 • Gaps/damage at the plenum should be sealed.
Distribution Condition Item: 2 • Air leaks were detected at the visible connections.

Roof System

Main Roof Condition Item: 1 • Damaged/Loose roofing material(s) were visible at multiple locations. An evaluation and repair should be completed by a qualified licensed roofer.

Interior Features

Window(s) Condition Item: 2 • Window tension spring(s) were damaged at multiple locations.
• Locks were missing/damaged at family room.
Smoke Detector Condition Item: 6 • Smoke detectors were not present/installed at all required areas.
• CO detector(s) were not present and should be installed for safety.

• Smoke detector(s) did not respond when tested at Hallway.

Kitchen

Kitchen Sink Condition Item: 3 • Moisture stains/damage was visible under sink.
Dishwasher Condition Item: 5 • Dishwasher did not operate under normal operating conditions.
Oven/Stove-top Condition Item: 6 • Oven was not functioning properly.

Bathrooms

Toilet(s) Condition Item: 3 • Toilet was loose at the floor at all bathrooms.
Shower(s) Condition Item: 4 • Wall at the exterior of shower enclosure was damaged at the primary bathroom.